Features of
Xstream Intensifier Pump

Nominal Power Rating50 hp (37 kW)
Maximum Continuous Pressure60,000 psi (4,137 bar)
Maximum Water Flow Rate at Maximum Pressure1.0 gpm (3.8 lpm)
Maximum Single Orifice Diameter (at full pressure).014″ (.36 mm)
Control Voltage & Power Supply24 VDC, 5 A
Maximum Noise LevelTBD
Ambient Operating Temperature40-104°F (4-40°C)
Air Supply VolumeStatic Application (virtually 0)
Air Supply Pressure85 psi (5.9 bar)
Length86.4″ (2,195 mm)
Width37.7″ (958 mm)
Height57.6″ (1,463 mm) with top covers
WeightTBD
Minimum Inlet Cutting Water Pressure30 psi (2 bar)
Plunger Diameter.866″(22 mm)
Nominal Strokes per Minute running max orifice at max pressure80
Accumulator Volume1.29 liter
Maximum Hydraulic Pressure3200 psi (221 bar)
Hydraulic Reservoir Capacity41 gal (155 L)
Cooling water consumption @ 75°F(24°C) Water Temperature2.0 gpm (7.6 Lpm)
Minimum Cooling Water Pressure30 psi (2 bar)
Redundant Topworks (option)
Booster Pump with Filter (included)
Wye-delta Starter (option)
Dual Pressure Compensator (included)
Proportional Control (option)
Remote Online Monitoring (option)
Nominal Power Rating30 hp (22 kW)
Maximum Continuous Pressure60,000 psi (4,137 bar)
Maximum Water Flow Rate at Maximum Pressure.6 gpm (2.3 Lpm)
Maximum Single Orifice Diameter (at full pressure).011″ (.28 mm)
Control Voltage & Power Supply24 VDC, 5 A
Maximum Noise LevelTBD
Ambient Operating Temperature40-104°F (4-40°C)
Air Supply VolumeStatic Application (virtually 0)
Air Supply Pressure85 psi (5.9 bar)
Length86.4″ (2,195 mm)
Width37.7″ (958 mm)
Height57.6″ (1,463 mm) with top covers
WeightTBD
Minimum Inlet Cutting Water Pressure30 psi (2 bar)
Plunger Diameter.866″ (22 mm)
Nominal Strokes per Minute running max orifice at max pressure50
Accumulator Volume1.29 Liter
Maximum Hydraulic Pressure3200 psi (221 bar)
Hydraulic Reservoir Capacity41 gal (155 L)
Cooling water consumption @ 75°F(24°C) Water TemperatureTBD
Minimum Cooling Water Pressure30 psi (2 bar)
Redundant Topworks (option)
Booster Pump with Filter (included)
Wye-delta Starter (option)
Dual Pressure Compensator (included)
Proportional Control (option)
Remote Online Monitoring (option)
Nominal Power Rating50 hp (37 kW)
Maximum Continuous Pressure85,000 psi (5,862 bar)
Maximum Water Flow Rate at Maximum Pressure.7 gpm (2.6 Lpm)
Maximum Single Orifice Diameter (at full pressure).010″ (.25 mm)
Control Voltage & Power Supply24 VDC, 5 A
Maximum Noise LevelTBD
Ambient Operating Temperature40-104°F (4-40°C)
Air Supply VolumeStatic Application (virtually 0)
Air Supply Pressure70 psi (4.8 bar)
Length86.4″ (2,195 mm)
Width37.7″ (958 mm)
Height57.6″ (1,463 mm) with top covers
WeightTBD
Minimum Inlet Cutting Water Pressure30 psi (2 bar)
Plunger Diameter.709″ (18 mm)
Nominal Strokes per Minute running max orifice at max pressureTBD
Accumulator Volume1.1 Liter
Maximum Hydraulic Pressure2950 psi (203 bar)
Hydraulic Reservoir Capacity41 gal (155 L)
Cooling water consumption @ 75°F(24°C) Water TemperatureTBD
Minimum Cooling Water Pressure30 psi (2 bar)
Redundant Topworks (option)
Booster Pump with Filter (included)
Wye-delta Starter (option)
Dual Pressure Compensator (included)
Proportional Control (option)
Remote Online Monitoring (option)

OEM Application